<?xml version="1.0" encoding="UTF-8" standalone="yes"?><ns2:messageList xmlns:ns2="http://esuite.pjm.com/"><messages><appearanceFlag>true</appearanceFlag><applicationIds>12</applicationIds><applicationIds>15</applicationIds><applications>Markets Gateway</applications><applications>Messages</applications><blockAccessFlag>false</blockAccessFlag><changeEnd>2026-12-31T05:00:00Z</changeEnd><changeStart>2026-01-08T05:00:00Z</changeStart><effectiveDate>2026-01-08T05:00:00Z</effectiveDate><message>&lt;h4 style="margin: 0px 0px 0px"&gt;Increased Reserve Requirements&lt;/h4&gt;&lt;h5 style="font-weight: bold; margin: 20px 0px 10px 0px"&gt;1.8.2026 00:00 to 12.31.2026 00:00&lt;/h5&gt;&lt;p style="margin: 0px 0px 0px"&gt;&lt;p&gt;Due to the non-performance of committed Synchronized Reserve resources during Synchronized Reserve Events since the implementation of Reserve Price Formation (October 1, 2022) and to maintain compliance with NERC Standards, effective from May 19, 2023, PJM carried an additional 30% on the Reliability requirement component of Synchronized and Primary reserve in the RTO only in the Day-Ahead, and Real-time Markets for all hours. Effective January 9, 2026 instead of 30% PJM will carry an additional 20% on the Reliability requirement component of Synchronized and Primary reserve in the RTO only in the Day-Ahead, and Real-time Markets for all hours until further notice.&lt;/p&gt;&lt;p&gt;&lt;br /&gt;&lt;/p&gt;&lt;p&gt;For example (rounded to whole MW): If the largest single contingency = 1,630 MW&lt;/p&gt;&lt;p&gt;&lt;br /&gt;&lt;/p&gt;&lt;p&gt;&lt;strong&gt;Default (100% of largest contingency)&lt;/strong&gt;&lt;/p&gt;&lt;p&gt;Synchronized Reserve requirement: 1,630*1 + 190 = 1,820 MW&lt;/p&gt;&lt;p&gt;Primary Reserve requirement: 1,630*1.5 + 190 = 2,635 MW&lt;/p&gt;&lt;p&gt;30-Minute Reserve requirement: Max(3,000, gas contingency, PR reliability) + 190 = 3,190 MW&lt;/p&gt;&lt;p&gt;&lt;br /&gt;&lt;/p&gt;&lt;p&gt;&lt;strong&gt;Increased reliability by 20%&lt;/strong&gt;&lt;/p&gt;&lt;p&gt;Synchronized Reserve requirement: 1,630*1.2 + 190 = 2,146 MW&lt;/p&gt;&lt;p&gt;Primary Reserve requirement: 1,630*1.2*1.5 + 190 = 3,124 MW&lt;/p&gt;&lt;p&gt;30-Minute Reserve requirement: Max(3,000, gas contingency, PR reliability) + 190 = 3000 + 190 = 3,190 MW&lt;/p&gt;&lt;p&gt;&lt;br /&gt;&lt;/p&gt;&lt;p&gt;If you have any questions regarding this message, please contact PJM Customer Service at (866) 400-8980 or send an email to &lt;a href="mailto:custsvc@pjm.com" target="_new" target="_blank" rel="nofollow noopener noreferrer"&gt;custsvc@pjm.com&lt;/a&gt;. Thank you.&lt;/p&gt;&lt;/p&gt;</message><messageActions>No action required/information only</messageActions><messageActions>Please share within your organization</messageActions><messageRaw>&lt;p&gt;Due to the non-performance of committed Synchronized Reserve resources during Synchronized Reserve Events since the implementation of Reserve Price Formation (October 1, 2022) and to maintain compliance with NERC Standards, effective from May 19, 2023, PJM carried an additional 30% on the Reliability requirement component of Synchronized and Primary reserve in the RTO only in the Day-Ahead, and Real-time Markets for all hours. Effective January 9, 2026 instead of 30% PJM will carry an additional 20% on the Reliability requirement component of Synchronized and Primary reserve in the RTO only in the Day-Ahead, and Real-time Markets for all hours until further notice.&lt;/p&gt;&lt;p&gt;&lt;br /&gt;&lt;/p&gt;&lt;p&gt;For example (rounded to whole MW): If the largest single contingency = 1,630 MW&lt;/p&gt;&lt;p&gt;&lt;br /&gt;&lt;/p&gt;&lt;p&gt;&lt;strong&gt;Default (100% of largest contingency)&lt;/strong&gt;&lt;/p&gt;&lt;p&gt;Synchronized Reserve requirement: 1,630*1 + 190 = 1,820 MW&lt;/p&gt;&lt;p&gt;Primary Reserve requirement: 1,630*1.5 + 190 = 2,635 MW&lt;/p&gt;&lt;p&gt;30-Minute Reserve requirement: Max(3,000, gas contingency, PR reliability) + 190 = 3,190 MW&lt;/p&gt;&lt;p&gt;&lt;br /&gt;&lt;/p&gt;&lt;p&gt;&lt;strong&gt;Increased reliability by 20%&lt;/strong&gt;&lt;/p&gt;&lt;p&gt;Synchronized Reserve requirement: 1,630*1.2 + 190 = 2,146 MW&lt;/p&gt;&lt;p&gt;Primary Reserve requirement: 1,630*1.2*1.5 + 190 = 3,124 MW&lt;/p&gt;&lt;p&gt;30-Minute Reserve requirement: Max(3,000, gas contingency, PR reliability) + 190 = 3000 + 190 = 3,190 MW&lt;/p&gt;&lt;p&gt;&lt;br /&gt;&lt;/p&gt;&lt;p&gt;If you have any questions regarding this message, please contact PJM Customer Service at (866) 400-8980 or send an email to &lt;a href="mailto:custsvc@pjm.com" target="_new" target="_blank" rel="nofollow noopener noreferrer"&gt;custsvc@pjm.com&lt;/a&gt;. Thank you.&lt;/p&gt;</messageRaw><subject>Increased Reserve Requirements</subject><terminateDate>2026-12-31T05:00:00Z</terminateDate><userMessageId>5678</userMessageId></messages><messages><appearanceFlag>true</appearanceFlag><applicationIds>75</applicationIds><applications>NextGen</applications><blockAccessFlag>false</blockAccessFlag><changeEnd>2026-07-31T16:05:00Z</changeEnd><changeStart>2026-07-31T16:00:00Z</changeStart><effectiveDate>2026-07-28T13:25:00Z</effectiveDate><message>&lt;h4 style="margin: 0px 0px 0px"&gt;The EIT application window will open on 7/31/26 at 12pm EPT in NextGen.&lt;/h4&gt;&lt;h5 style="font-weight: bold; margin: 20px 0px 10px 0px"&gt;7.31.2026 from 12:00 to 12:05&lt;/h5&gt;&lt;p style="margin: 0px 0px 0px"&gt;&lt;p&gt;The Expedited Interconnection Track application window will open on 7/31/26 at 12pm EPT in NextGen.&lt;/p&gt;&lt;/p&gt;</message><messageActions>No action required/information only</messageActions><messageActions>Please share within your organization</messageActions><messageRaw>&lt;p&gt;The Expedited Interconnection Track application window will open on 7/31/26 at 12pm EPT in NextGen.&lt;/p&gt;</messageRaw><subject>The EIT application window will open on 7/31/26 at 12pm EPT in NextGen.</subject><terminateDate>2026-08-25T03:59:00Z</terminateDate><userMessageId>5971</userMessageId></messages><messages><appearanceFlag>true</appearanceFlag><applicationIds>40</applicationIds><applications>eGADS</applications><blockAccessFlag>false</blockAccessFlag><changeDuration>Up to 30 Minutes</changeDuration><changeEnd>2026-08-10T17:00:00Z</changeEnd><changeStart>2026-08-10T15:00:00Z</changeStart><effectiveDate>2026-08-08T04:00:00Z</effectiveDate><message>&lt;h4 style="margin: 0px 0px 0px"&gt;Maintenance to eGADS in Prod. on August 10 from 11:00 a.m. - 1:00 p.m. EPT&lt;/h4&gt;&lt;h5 style="font-weight: bold; margin: 20px 0px 10px 0px"&gt;Today from 11:00 to 13:00&lt;/h5&gt;&lt;p style="margin: 0px 0px 0px"&gt;&lt;p&gt;&lt;span style="color:black"&gt;PJM will be performing system maintenance in the &lt;/span&gt;&lt;strong style="color:black"&gt;Production&lt;/strong&gt;&lt;span style="color:black"&gt; environment on &lt;/span&gt;&lt;strong style="color:black"&gt;Monday, August 10, 2026&lt;/strong&gt;&lt;span style="color:black"&gt;, from &lt;/span&gt;&lt;strong style="color:black"&gt;11:00 a.m. - 1:00 p.m. &lt;/strong&gt;&lt;span style="color:black"&gt;EPT (1100-1300 hours). During this maintenance, there will be an&lt;/span&gt;&lt;strong style="color:black"&gt; outage of up to 30 minutes.&lt;/strong&gt;&lt;/p&gt;&lt;p&gt;&lt;strong style="color:black"&gt;Impacted Tool&lt;/strong&gt;&lt;/p&gt;&lt;p&gt;&lt;span style="color:black"&gt;eGADS&lt;/span&gt;&lt;/p&gt;&lt;/p&gt;</message><messageActions>Users will be unable to access tool or website</messageActions><messageActions>Please share within your organization</messageActions><messageActions>Users must sign out of tool or website before start time</messageActions><messageImpacts>Tool or website outage</messageImpacts><messageImpacts>Re-login</messageImpacts><messageRaw>&lt;p&gt;&lt;span style="color:black"&gt;PJM will be performing system maintenance in the &lt;/span&gt;&lt;strong style="color:black"&gt;Production&lt;/strong&gt;&lt;span style="color:black"&gt; environment on &lt;/span&gt;&lt;strong style="color:black"&gt;Monday, August 10, 2026&lt;/strong&gt;&lt;span style="color:black"&gt;, from &lt;/span&gt;&lt;strong style="color:black"&gt;11:00 a.m. - 1:00 p.m. &lt;/strong&gt;&lt;span style="color:black"&gt;EPT (1100-1300 hours). During this maintenance, there will be an&lt;/span&gt;&lt;strong style="color:black"&gt; outage of up to 30 minutes.&lt;/strong&gt;&lt;/p&gt;&lt;p&gt;&lt;strong style="color:black"&gt;Impacted Tool&lt;/strong&gt;&lt;/p&gt;&lt;p&gt;&lt;span style="color:black"&gt;eGADS&lt;/span&gt;&lt;/p&gt;</messageRaw><subject>Maintenance to eGADS in Prod. on August 10 from 11:00 a.m. - 1:00 p.m. EPT</subject><terminateDate>2026-08-13T04:00:00Z</terminateDate><userMessageId>5983</userMessageId></messages></ns2:messageList>